Analiza strujanja vazduha u data centru
##plugins.themes.bootstrap3.article.main##
Apstrakt
Vazduh je glavni prenosilac toplote i vlage u data centru. Bitno je optimizovati putanje proticanja kako za snabdevanje hladnim vazduhom tako i za odvođenje toplog vaduha. Trajno povećanje rashladnog opterećenja nametnulo je potrebu da se analizira protok vazduha u data centrima. Cilj je upravljati protokom vazduha nezavisno od svih faktora koji ga ograničavaju. Protok vazduha u postojećem data centru je analiziran korišćenjem programskog paketa PHOENICS. Dimenzije centra su 18 m x 18 m x 13 m i Datacom oprema je postavljena na podignuti pod. Korišćenjem modela i fizičkih mera dobijen je termalni profil
polja pritisaka i brzine u centru.
##plugins.themes.bootstrap3.article.details##
Kako citirati
STAVREVA, Sevde K.; SERAFIMOV, Marko; ANDREEVSKI, Igor B..
Analiza strujanja vazduha u data centru.
Zbornik Međunarodnog kongresa o procesnoj industriji – Procesing, [S.l.], v. 25, n. 1, apr. 2017.
Dostupno na: <http://www.izdanja.smeits.rs/index.php/ptk/article/view/2392>. Datum pristupa: 13 nov. 2026
Sekcija
Tehnička regulativa, standardizacija i sistem kvaliteta
Reference
Journals
[1] Beaty, D., and T. Davidson, New guideline for data center cooling, ASHRAE Journal, 45 (12), pp. 28-34, 2003
[2] Beaty, D., and T. Davidson, Data centers- Datacom airflow patterns , ASHRAE Journal, 47 (4), pp. 50-54, 2005
Books
[3] ASHRAE TC9.9: High Density Data Centers, ASHRAE Special Publications, 2008
[4] ASHRAE TC9.9: Thermal Guidelines for Data Processing Environments, 2004
[5] Gupta, A.K. and Lilley, D.G.: Flowfield Moddeling and Diagnostics
Chapters
[6] ASHRAE TC9.9: Best Practices for Datacom Facility Energy Efficiency, ASHRAE Special Publications, 2004, pp. 73-84
[7] Patankar, S.V., and K. C. Karki, Distribution of cooling airflow in a raised floor data center, ASHRAE Transactions, pp. 629-634, 2004
[8] Sorell, V., S. Escalante, and J.Yang, Comparison of overheat and underfloor air delivery systems in a data center environment using CFD Modeling, ASHRAE Transactions 111, pp. 756-764, 2005
[1] Beaty, D., and T. Davidson, New guideline for data center cooling, ASHRAE Journal, 45 (12), pp. 28-34, 2003
[2] Beaty, D., and T. Davidson, Data centers- Datacom airflow patterns , ASHRAE Journal, 47 (4), pp. 50-54, 2005
Books
[3] ASHRAE TC9.9: High Density Data Centers, ASHRAE Special Publications, 2008
[4] ASHRAE TC9.9: Thermal Guidelines for Data Processing Environments, 2004
[5] Gupta, A.K. and Lilley, D.G.: Flowfield Moddeling and Diagnostics
Chapters
[6] ASHRAE TC9.9: Best Practices for Datacom Facility Energy Efficiency, ASHRAE Special Publications, 2004, pp. 73-84
[7] Patankar, S.V., and K. C. Karki, Distribution of cooling airflow in a raised floor data center, ASHRAE Transactions, pp. 629-634, 2004
[8] Sorell, V., S. Escalante, and J.Yang, Comparison of overheat and underfloor air delivery systems in a data center environment using CFD Modeling, ASHRAE Transactions 111, pp. 756-764, 2005